Margo Rubber Products
Three-hole rubber cable grommet
SHORE A
±5 pts against the specified hardness
TENSILE
Per compound datasheet, tested to ASTM D412

Grommets

3 Pin Hole Pad — Three-Way Electrical Pass-Through Grommet

A moulded rubber pass-through with three cable holes, for taking a harness through a panel without letting water, dust or noise follow it, and without the panel edge cutting into the cable. Sized to your panel gauge, hole pitch and wire diameter.

HARDNESS
50–60 Shore A typical for a pass-through grommet, 40–90 available
TEMPERATURE
−40 to +140 °C on the default EPDM
PANEL GAUGE
To your drawing — sizes the retaining groove
HOLES
3 · diameters and pitch to your drawing
QTY (pieces)
−10,000+
Minimum run: 10,000 pieces per part number
  • MADE TO ORDER
  • ISO 9001:2015
  • 09111526A

Product gallery

Visual Reference

360° PREVIEW

Loading 3D model…

Drag to rotate · Scroll to zoom

Cross section viewSectioned profile through the retaining groove — on request under NDA

Hole diameters
Three, stated individually
Hole pitch
Centre distances between the three holes
Interference
How far each hole is undersized against its wire
Fitting direction
Which face goes to the wet side

Sectioned profile available on request. Send the panel gauge, the hole diameter in the panel, and the three wire diameters — or a sample grommet and a piece of the panel — and we will return a dimensioned drawing for approval.

Technical specifications

Engineering Data

Product Family
Grommets
Material
EPDM standard; NBR or neoprene where oil is present
Hardness (Shore A)
50–60 typical, 40–90 available
Tensile Strength
Per compound datasheet, tested to ASTM D412
Elongation at Break
Per compound datasheet, ASTM D412
Operating Temperature
−40 to +140 °C on EPDM; see section 03 for the others
Compression Set
Tested to ASTM D395 Method B
Density
Per compound datasheet
Colour Options
Black standard, custom RAL on request
Lead Time
Confirmed with the quotation, from approved drawing and approved sample
Tear strength
Tested to ASTM D624
Panel gauge range
To your drawing
Hole configuration
3 holes; diameters, pitch and interference to your drawing
Certifications
ISO 9001:2015 — certificate 09111526A, valid to 21 February 2027
Minimum Order
10,000 pieces per part number, per compound, or quoted against the part where geometry or tooling makes that unrealistic. Prototype and first-article lots sit outside the minimum.

Dimensional reference

To customer drawing
Hole diameters
Three, stated individually
Hole pitch
Centre distances between the three holes
Interference
How far each hole is undersized against its wire
Fitting direction
Which face goes to the wet side

Available materials

Rubber Compound Options

Select the compound best suited to your operating environment and application requirements.

Compound

EPDM

Ethylene Propylene Diene Monomer

Temperature range

−40 to +140 °C

For this part

The default. Water, weather, ozone and UV — a body or bulkhead pass-through spends its life exposed to all four

Not sure? Send the medium, temperature and load

Three-hole rubber cable grommet

FITTED HARDNESS

50–60 Shore A

soft enough to seat, firm enough to grip

Key advantages

Why Specifiers Choose Margo

  • It has to fit before it can seal

    A grommet is seated by hand over a cut panel edge. We specify hardness and tear strength for that moment, not just for service life — a part the operator has to force is a part that gets damaged on the line.

  • The seal is the interference

    Each hole is moulded undersize against its wire. Send the wire diameters and we will set the interference — matching hole to wire exactly gives a grommet that passes inspection and leaks in service.

  • Sized to your panel, not to a catalogue

    Panel gauge sets the retaining groove; hole pitch is fixed by your harness. Both are moulded in, so the part seats in one push and stays put.

  • Protecting the cable is half the job

    A chafed harness is a short circuit, so the bore is moulded with a radius rather than cut, and the compound is chosen to stay flexible cold.

Industries served

Global Applications

  • Automotive

    Bulkhead and floor-pan harness pass-throughs, door-to-body cable transitions, lamp and switch wiring

  • Electrical & Enclosures

    Control panels, junction boxes and outdoor cabinets, where the grommet is what carries the enclosure’s IP rating under IEC 60529

  • Heavy Industry

    Harness entries on machine enclosures and control cabinets, where dust and washdown are the threats

  • Infrastructure

    Cable entries on roadside cabinets, pump housings and site equipment

Manufacturing process

From Compound to Certification

  1. Material compounding

    Polymer blending, additive integration and batch QC in our in-house lab. Tear strength is set here — the grommet is stretched over a cut panel edge by hand, and that moment decides line scrap.

  2. Mould Design & CNC

    Mould design and CNC tool manufacture, in-house, held as a controlled record. The retaining groove and the three cores are cut to your panel gauge and hole pitch.

  3. Compression Moulding

    Hydraulic press cycles at controlled temperature and pressure profiles per product spec.

  4. Post-cure and deflashing

    Flash removed from the three bores and the groove. Flash left in a bore is a leak path and a chafe point.

  5. Quality inspection

    Hole diameters, pitch and groove dimension checked against the drawing, plus hardness testing and batch sampling.

  6. Export packaging

    Industrial packing with documentation. ISPM-15 treated pallets where timber packaging is used. Grommets are bagged loose so the sealing lips are not deformed in transit.

Quality assurance

Certified to International Standards

Every product leaves our facility with a documentation package — material test reports, dimensional inspection sheets and a certificate of conformance — giving traceability from raw material to finished part.

  • ISO 9001:2015 · Certificate 09111526A

    Integral Certification Ltd · Valid to 21 February 2027

    Scope: rubber moulded components — this part is within scope

  • IATF 16949 — upgrade in progress, certification targeted by end 2026

  • ISO 14001 and ISO 45001 — targeted 2027

Certification detail

Production metrics

Since 2005
In operation
60+
Active clients
3–4 weeks from approved sample
Avg. lead time

Downloads

Technical Documentation

Dimensioned drawings and 3D models are issued on request, under NDA where required. Send the panel gauge, hole diameter and the three wire sizes — or a sample and a panel offcut — and we will return a drawing for approval.

Request a drawing

FAQ

Technical & Commercial Questions

Answers to the most common questions from engineering teams and procurement managers worldwide.

  • What is the minimum order quantity for this part?

    We supply in bulk. The minimum run is 10,000 pieces per part number, per compound, or quoted against the part where geometry or tooling makes that unrealistic. Prototype and first-article lots sit outside the minimum.

  • Can you match a competitor specification or reverse-engineer an existing part?

    Yes. Send the sample and a piece of the panel it fits. The groove has to match the panel gauge, and a used grommet has relaxed — we measure the panel, not the worn part, and set the hole interference from your wire sizes.

  • What file formats do you accept for drawings?

    PDF, DWG, DXF and STEP. Mark the panel gauge, the panel hole diameter, the three wire diameters and the hole pitch — those four, plus the compound, are enough for us to quote and tool.

  • Do you provide material test reports with each shipment?

    Yes. Material test reports, dimensional inspection sheets and a certificate of conformance ship with every consignment. Hardness, tensile to ASTM D412, compression set to ASTM D395 Method B and tear strength to ASTM D624 are tested in-house.

  • What are your payment and delivery terms for international orders?

    TT and LC accepted, discussed per order. Ex-works Nashik or FOB Nhava Sheva. Commercial invoice, packing list and certificate of origin are issued with every consignment.

Same compound

Other parts we mould in the same compounds

Need this part quoted?

Send your drawing, or a sample grommet with a piece of the panel. We confirm compound, hardness and the hole interference, then quote against your annual quantity. We respond within 48 hours.